Telecom base stations
House communications, power and battery equipment in a serviceable outdoor enclosure.
A 300–5000 W cabinet air-conditioner range with RS485 and dry-contact interfaces, selected from enclosure heat load, ambient design temperature and mounting requirements.
The source lists AC0300X/H, AC0500X/H, AC0800X, AC1000X/H, AC1500X/H, AC2000X/H and higher-capacity H variants through AC5000H. The range uses R134a refrigerant and source-listed IP55 protection.
RS485 and dry-contact interfaces are listed for communications and alarms. Electrical input is specified as 187–253 V AC, 50 Hz; confirm the exact model's electrical data and interface functions.
The telecom cabinet air conditioner range covers small equipment enclosures through higher-heat-load communications and power cabinets. X and H variants provide different model choices within a published 300–5000 W cooling range.
Cooling capacity is one selection input. Cabinet insulation, solar exposure, internal dissipation and the target equipment temperature must be considered together before a model is selected.
Huijue Group can review OEM thermal units, private-label identification and cabinet interfaces developed from samples or drawings. Engineering feasibility, tooling, thermal and electrical tests, order quantity and delivery scope must be confirmed for any variation.
Provide enclosure dimensions and insulation, heat load, ambient and internal targets, supply, mounting drawing, drainage arrangement and monitoring requirements.
| Models | AC0300X/H, AC0500X/H, AC0800X, AC1000X/H, AC1500X/H, AC2000X/H, AC2500H, AC3000H, AC4000H, AC5000H |
|---|---|
| Cooling capacity range | 300–5000 W |
| AC input | 187–253 V AC, 50 Hz |
| Operating temperature | -40°C to 55°C |
| Communication | RS485 / dry contact |
| Protection | IP55 |
| Refrigerant | R134a |
The published operating range is −40°C to +55°C. Confirm cooling performance at the project's design point and the installed enclosure protection at the mounting interface.
Buyer Questions
Answers specific to Telecom Cabinet Air Conditioner selection, configuration and purchasing.
Use a cabinet heat calculation that includes equipment dissipation, solar gain, insulation and the required temperature difference. Confirm performance at the design ambient.
The record does not establish heating for every model. Specify whether heating is required and confirm the selected unit's functions.
Confirm protocol, register map, addressing and supported alarms. The interface name alone does not establish platform compatibility.
The listed supply is 50 Hz. Submit any other electrical requirement for engineering review before ordering.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
House communications, power and battery equipment in a serviceable outdoor enclosure.
Protect distributed equipment while maintaining cable entry and service access.
Coordinate cabinet capacity, thermal management and equipment zoning.
Fit protected infrastructure into space-constrained or visually sensitive locations.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.