HR2000 Row-Based Modular Data Center

HR2000 Row-Based Modular Data Center

A single-row micro-module architecture combining IT cabinets with integrated power, UPS, cooling and monitoring infrastructure for compact indoor data-center projects.

Product Features

  • Single-row cold-channel arrangement with a reference range of 1–8 cabinets.
  • Cabinet dimensions listed as 2000 or 2200 mm high, 600 mm wide and 1400 mm deep.
  • 42U or 46U rack format per cabinet.
  • 12.5 kW cooling reference at L35/L35 with 380 V AC, 50 Hz input.
  • 20 kVA UPS reference and a 20 kW supported IT-load figure in the source configuration.
  • Local 10-inch display and remote web monitoring; optional environmental and access sensors.

The HR2000 Row-Based Modular Data Center arranges IT cabinets around an infrastructure cabinet that brings together power distribution, UPS, refrigeration and monitoring. The documented row forms a cold-air passage and allows IT cabinets to extend on either side of the infrastructure position.

This approach suits a project where room infrastructure must be coordinated as a package rather than purchased as unrelated cabinet, cooling and power items. The final row configuration remains dependent on the equipment schedule, available room services and the intended expansion sequence.

Selection & Configuration

Develop the row from per-cabinet loads and a rack elevation. The source separately lists 6 kW maximum per cabinet, so the selected population must also remain within the whole-system power and cooling design. Specify UPS architecture, battery autonomy and single or dual feeds, and confirm which components are shared across the row.

Check aisle access, heat rejection, floor loading and installation route before agreeing the package dimensions.

Manufacturing & Customization

Huijue Group can assess an OEM or private-label HR2000 project from layout drawings and equipment references, including sample-based interface work. Cabinet combinations, power architecture and controls require engineering confirmation of tooling, tests, quantities and delivery scope.

Information for an Accurate Quotation

Provide cabinet count, rack elevations, present and future IT loads, AC service, redundancy requirement, autonomy target, room drawing, cooling connections and monitoring points.

Technical Parameters

Single Row Configuration Table
Cabinet systemCooling System
Dimensions (H x W x D MM)2000(2200)X 600X 1400Rated AC input power supply380V AC 50Hz
System Layout / ConfigurationSingle row, cold aisleCooling capacity (L35/L35)12.5KW
Number of single cabinets1-8 unitsRated Input Power3.5KW
Capacity42U (46U) * number of cabinetsRated current19.5A
Protection RatingIP30Heating Capacity3KW
Operating Temperature-20℃~45℃RefrigerantR410A
InstallationConcrete floor, raised floorSensible Heat Ratio (SHR)≥0.99
Maximum load per cabinet6KWEnergy Efficiency Ratio≥3.2
Supports maximum power consumption of IT load20KWAir distributionFront air supply, rear air return
IT cabinet bearing requirementsStatic load 1500kg, dynamic load 1000kgInstallationInter-row installation
• Distribution SystemMonitoring system
Lightning protection levelClass C, In 20ka, Imax40kaMonitoring systemSupport remote web interface access
Power InputSingle and dual channels optionalLocal InterfaceStandard 10-inch touch screen
Dual Power Switching SystemOptional for 2-way inputMobile O&MMobile App, SMS Alerts
UPS Capacity20KVASmoke detectorOptional
UPS ArchitectureN、N+1、2NWater Leak DetectionOptional
Input Voltage380V Three Phase 3Ph + N + PeTemperature and humidityOptional
Output voltage220V~240V AC 50Hz 380V~400V AC 50HzDoor LockOptional
Output power factor0.9Video monitoringOptional
Backup time15~30minFire Suppression System
Maintenance BypassStandardFire Suppression UnitHeptafluoropropane Cabinet-Type Fire Suppression Unit (Non-Piped)

Applications

  • Small indoor IT rooms.
  • Enterprise or edge sites requiring a single equipment row.
  • Projects coordinating cabinet, power and cooling expansion.

Installation Notes

The source lists IP30, -20°C to 45°C operation, and concrete- or raised-floor installation. Room temperature and heat rejection must be checked against the selected cooling configuration.

Buyer Questions

Frequently Asked Questions

Answers specific to HR2000 Row-Based Modular Data Center selection, configuration and purchasing.

Can eight fully populated 6 kW cabinets be assumed from the references?

No. The source has separate cabinet, IT-load, UPS and cooling references. The final number and loading must be engineered as one configuration.

What is integrated into the infrastructure cabinet?

The documented concept combines power distribution, UPS, refrigeration and monitoring. Confirm the exact installed equipment and optional systems in the project bill of materials.

How should future expansion be specified?

Show future cabinets, projected loads and space on the initial layout. Power, cooling and shared infrastructure capacity must be checked for the expansion stage.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Equipment rooms

Organize racks, pathways and service access around active network equipment.

Data centers

Coordinate cabinet capacity, cable routes, airflow and planned expansion.

Edge facilities

Package network equipment within compact distributed infrastructure sites.

Retrofit projects

Add capacity while accounting for existing racks, routes and maintenance space.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.