Single-Sided Cold Aisle Containment

Single-Sided Cold Aisle Containment

A modular cold-air containment assembly with roof sections, access doors and side closure components for defining a supplied-air passage beside equipment cabinets.

Product Features

  • Modular units connect at the cabinet-front zone and can be serviced individually.
  • Door assemblies are listed for 1000 mm and 1200 mm passage widths.
  • Roof and sealing components address 300 mm, 600 mm and 800 mm cabinet widths.
  • False-wall and wall-support components are included in the source assembly schedule.
  • Threshold-free access, fire-linked movable roof sections and an emergency switch are described.

Single-Sided Cold Aisle Containment forms a contained supply-air passage at the front of equipment cabinets. Roof, door and closure components help keep supplied cold air on the intended path to equipment inlets.

The documented cooling arrangement feeds the passage through a raised floor and returns heated room air at high level. Containment therefore needs to be designed with the room’s air supply and return provisions; it does not generate cooling by itself.

Selection & Configuration

Provide a plan and elevation showing cabinet heights, row length, wall interfaces and all gaps that need closure. The reference range covers 6–15 cabinets, 1–8 kW per cabinet and 24–100 kW total; these describe a design envelope, not a guarantee that any combination within those limits has sufficient cooling.

Confirm manual or automatic doors, door access controls, fire-signal interfaces and the roof-opening sequence with the site's responsible designers.

Manufacturing & Customization

Huijue Group can review unilateral containment from a room drawing, sample component or OEM specification, including private-label identification. Interface details, tooling, functional tests, quantity and delivery scope need engineering confirmation.

Information for an Accurate Quotation

Supply aisle width, cabinet dimensions, row count, heat load, floor-air outlet layout, wall details, door selection and the required fire and monitoring interfaces.

Technical Parameters

Unilateral Cold Aisle Closure Assembly – Aisle Door
S/NModelNAMEPRODUCT FEATURES
1HJD-MEN-01Access doorApplicable to 1000mm wide channel, manual sliding door, steel door frame, embedded tempered glass, with door lock
2HJD-MEN-02Applicable to 1000mm wide channel, automatic sliding door, steel door frame, embedded tempered glass, access lock with password, touch screen
3HJD-MEN-03Applicable to 1000mm wide channel, automatic sliding door, aluminum alloy door frame, embedded tempered glass, access lock with password, touch screen
4HJD-MEN-04Applicable to 1200mm wide channel, automatic sliding door, steel door frame, embedded tempered glass, with door lock
5HJD-MEN-05Applicable to 1200mm wide channel, automatic sliding door, steel door frame, embedded tempered glass, access lock with password, touch screen
6HJD-MEN-06Applicable to 1200mm wide channel, automatic sliding door, aluminum alloy door frame, embedded tempered glass, access lock with password, touch screen
7HJD-MEN-07Applicable to 1000mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, with door lock
8HJD-MEN-08Applicable to 1000mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, access lock with electronic password, electric touch screen
9HJD-MEN-09Applicable to 1200mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, with door lock
10HJD-MEN-010Applicable to 1200mm wide channel, sliding door, steel door frame, embedded tempered glass, hidden door closers, access lock with electronic password, electric touch screen
Unilateral Cold Aisle Closure Assembly – Active Skylight
S/NModelNAMEPRODUCT FEATURES
1HJL-HTC-01Event sunroofSuitable for 300 wide cabinet, 1000mm wide channel, steel frame + glass, with fire linkage
2HJL-HTC-02Suitable for 300 wide cabinet, 1200mm wide channel, steel frame + glass, with fire linkage
3HJL-HTC-03Suitable for 600 wide cabinet, 1000mm wide channel, steel frame + glass, with fire linkage
4HJL-HTC-04Suitable for 600 wide cabinet, 1200mm wide channel, steel frame + glass, with fire linkage
5HJL-HTC-05Suitable for 800 wide cabinet, 1000mm wide channel, steel frame + glass, with fire linkage
6HJL-HTC-06Suitable for 800 wide cabinet, 1200mm wide channel, steel frame + glass, with fire linkage
Single Side Cold Aisle Closure Assembly – Functional Skylight
S/NModelNAMEPRODUCT FEATURES
1HJL-GTC-01Functional skylightSuitable for 300 wide cabinet, 1000mm wide channel, steel plate production, with fire linkage control box, sensor installation position
2HJL-GTC-02Suitable for 300 wide cabinet, 1200mm wide channel, steel plate production, with fire linkage control box, sensor installation position
3HJL-GTC-03Suitable for 600 wide cabinet, 1000mm wide channel, steel plate production, with fire linkage control box, sensor installation position
4HJL-GTC-04Suitable for 600 wide cabinet, 1200mm wide channel, steel plate production, with fire linkage control box, sensor installation position
5HJL-GTC-05Suitable for 800 wide cabinet, 1000mm wide channel, steel plate production, with fire linkage control box, sensor installation position
6HJL-GTC-06Suitable for 800 wide cabinet, 1200mm wide channel, steel plate production, with fire linkage control box, sensor installation position
Single Side Cold Aisle Closure Assembly – Side Seal Plate
S/NModelNAMEPRODUCT FEATURES
1HJL-CFB-01Side Seal PlateSuitable for 300 wide cabinet, steel plate production
2HJL-CFB-02Suitable for 600 wide cabinet, steel plate production
3HJL-CFB-03Suitable for 800 wide cabinet, steel plate production
Unilateral Cold Aisle Closure Assembly – Control System
S/NModelNAMEPRODUCT FEATURES
1HJL-KZX-01the lighting systemIncluding sunroof lighting and infrared remote sensing switch
2HJL-KZX-02Monitoring systemIncludes monitoring unit and sensor
3HJL-KZX-03Fire control systemIncludes module power supply and sunroof controller
Unilateral Cold Aisle Closure Assembly – False Wall Assembly
S/NModelNAMEPRODUCT FEATURES
1HJL-JQZ-01Fake Wall AssemblySuitable for 300 wide, 2000 high cabinet, 1000mm wide channel, steel plate production
2HJL-JQZ-02Suitable for 300 wide, 2000 high cabinet, 1200mm wide channel, steel plate production
3HJL-GTC-03Suitable for 300 wide, 2200 high cabinet, 1000mm wide channel, steel plate manufacturing
4HJL-GTC-04Suitable for 300 wide, 2200 high cabinet, 1200mm wide channel, steel plate manufacturing
5HJL-GTC-05Suitable for 600 wide, 2000 high cabinet, 1000mm wide channel, steel plate production
6HJL-GTC-06Suitable for 600 wide, 2000 high cabinet, 1200mm wide channel, steel plate production
7HJL-GTC-07Suitable for 600 wide, 2200 high cabinet, 1000mm wide channel, steel plate manufacturing
8HJL-GTC-08Suitable for 600 wide, 2200 high cabinet, 1200mm wide channel, steel plate manufacturing
Single Side Cold Aisle Closure Assembly – Wall Support Plate
S/NModelNAMEPRODUCT FEATURES
1HJL-QZC-01Wall support plateSuitable for 300 wide cabinet, steel plate production
2HJL-QZC-02Suitable for 600 wide cabinet, steel plate production
3HJL-QZC-03Suitable for 800 wide cabinet, steel plate production

Applications

For server-room cabinet fronts where a contained cold-air supply path and wall-side closure must be coordinated with existing room infrastructure.

Installation Notes

Use within a designed equipment room. Check raised-floor air delivery, ceiling height, lighting, fire suppression access and safe movement through the passage.

Buyer Questions

Frequently Asked Questions

Answers specific to Single-Sided Cold Aisle Containment selection, configuration and purchasing.

Does the cold channel include an air conditioner?

This listing describes containment components. Cooling generation, airflow quantity and the room's supply and return system need a separate coordinated design.

What passage widths are documented?

Door and roof assemblies are listed for 1000 mm and 1200 mm widths. Identify the selected component set and cabinet widths on the project drawing.

How is the roof coordinated with fire suppression?

Movable roof sections are described with fire linkage. Signal requirements, opening behavior and on-site acceptance must be agreed with the fire-system designer.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Equipment rooms

Organize racks, pathways and service access around active network equipment.

Data centers

Coordinate cabinet capacity, cable routes, airflow and planned expansion.

Edge facilities

Package network equipment within compact distributed infrastructure sites.

Retrofit projects

Add capacity while accounting for existing racks, routes and maintenance space.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.