Telecom base stations
House communications, power and battery equipment in a serviceable outdoor enclosure.
A wall-mounted 10U sheet-metal enclosure with double-wall insulation and a fan-based configuration for small outdoor communications and supporting power equipment.
The JF02 Fan-Cooled Outdoor Cabinet is intended for small equipment installations that benefit from wall mounting. The listed HJ-XDF-JF02 assembly provides 10U of equipment space in a 600 × 600 × 600 mm cabinet.
Its equipment schedule should establish the ventilation arrangement explicitly. The fan configuration table is the basis for this product description; cooling substitutions require a separate review of the equipment heat and available supply.
Check wall capacity against the complete installed weight and locate the unit where doors and fan paths remain accessible. Deduct the rack units occupied by a power supply or monitor from the available equipment layout. Confirm actual fan quantity and cooling method in the approved bill of materials.
For JF02 orders, Huijue Group can review non-standard dimensions, OEM identification and private-label supply using customer drawings or samples. Mounting changes and thermal options need engineering feasibility, tooling, test, quantity and delivery-scope approval.
Provide the wall construction, equipment dimensions, occupied rack units, heat output, power feed and cable sizes.
| HJ-XDF-JF02 Product Configuration | |||||
|---|---|---|---|---|---|
| No. | Name | Specification | Qty | Unit | Remarks |
| 1 | 10U Fan-Cooled Outdoor Cabinet | 600*600*600 | 1 | Set | Includes uprights and internal structural parts; provides 10U equipment mounting space Double-wall structure |
| 2 | Shelves / L-Brackets | * | Set | Optional (1–3 pcs) | |
| 3 | Fans | Medium | 2 | Group | AC or DC optional |
| 4 | Wall-Mount Kit | 1 | Set | ||
| 5 | Door Magnetic Sensor | 1 | Set | ||
| 6 | Lamp | 1 | pc | ||
| 7 | Power Distribution Unit | AC / DC | 1 | Set | Optional |
| 8 | Power System | 3U, 60A | 1 | Set | Optional |
| 9 | Monitoring Unit | * | Set | Optional (sensors optional) | |
| 10 | Other Configuration | * | Set | Optional (customizable to customer requirements) | |
| 11 | Grounding Bar | 1 | Set | ||
| 12 | Accessories | Installation accessories | 1 | Set | Standard |
Small rooftop links, roadside communications devices and compact base-station auxiliaries are potential uses when the equipment fits the verified layout.
The source specifies IP55 or higher enclosure protection. Wall location, dust exposure, drainage around entries and ventilation maintenance remain project checks.
Buyer Questions
Answers specific to Fan-Cooled Outdoor Cabinet (Sheet Metal) JF02 selection, configuration and purchasing.
The source lists it as a 3U option. Show its position in the rack drawing and confirm remaining customer-equipment space.
Submit the thermal requirement for review. The agreed cooling unit, mounting changes and bill of materials must identify the supplied configuration.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
House communications, power and battery equipment in a serviceable outdoor enclosure.
Protect distributed equipment while maintaining cable entry and service access.
Coordinate cabinet capacity, thermal management and equipment zoning.
Fit protected infrastructure into space-constrained or visually sensitive locations.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.