Telecom base stations
House communications, power and battery equipment in a serviceable outdoor enclosure.
An insulated dual-cabinet arrangement with equipment and combined-function areas, configurable compressor cooling and bottom cable entry for outdoor communications equipment and battery integration.
Steel skins surround a 50 mm EPS or PU insulation core, with 2.0 mm internal load-bearing components. Front access is described, with rear-door options. Cooling can use compressor air conditioning, and an emergency fan is listed as an optional configuration item.
Bottom entry uses 8–16 cable glands; locking is three-point with internal fasteners. Battery racks, distribution, power systems and monitoring are defined by the order.
The Outdoor Weatherproof Thermostatic Cabinet uses sandwich-panel construction to organize outdoor equipment and supporting power or batteries. A combined-function cabinet and a separate equipment cabinet are described, allowing the layout to address service access and thermal zoning together.
The listed internal dimensions are 1800 × 800 × 800 mm per cabinet. Model labels in the source vary, so specify the physical arrangement and approved drawing when procuring this product rather than relying on a short model reference.
Allocate rack, power and battery functions between the cabinets before evaluating external footprint. Provide design temperatures and zone heat loads so the cooling equipment and control targets can be selected. The product name does not imply an unconditional internal temperature setpoint.
Huijue Group can review OEM or private-label insulated cabinet assemblies and customer sample or drawing requirements. Engineering must confirm revised dimensions, tooling, performance tests, quantity and delivery scope for the requested build.
Provide the two-cabinet layout, battery dimensions, heat dissipation, cooling supply, entry routes and preferred service-door arrangement.
| HJ-XDF-X02 Product Configuration | |||||
|---|---|---|---|---|---|
| No. | Name | Specification (H*W*D) | Qty | Unit | Remarks |
| 1 | Sandwich-Panel Outdoor Cabinet (Dual Cabinet) | Internal dimensions per cabinet 1800*800*800mm | 1 | Set | Dual cabinet (combined cabinet + equipment cabinet); includes uprights and internal structural parts; provides equipment mounting space, 1 battery rack set, 50 mm sandwich-panel structure, |
| 2 | Shelves / L-Brackets | * | Set | Optional (1–6 pcs) | |
| 3 | Air Conditioner | Compressor | * | Set | (Fan, heat exchanger, or air conditioner optional) |
| 4 | Base | 2 | Set | ||
| 5 | Emergency Fan | * | Set | Starts when air conditioner loses power | |
| 6 | Lamp | 2 | pc | ||
| 7 | Power Distribution Unit | AC / DC | * | Set | Optional |
| 8 | Power System | * | Set | Optional | |
| Generator Socket | * | Set | Optional | ||
| 8 | Battery | * | Set | Optional | |
| 9 | Monitoring Unit | * | Set | Optional (sensors optional) | |
| 10 | Other Configuration | * | Set | Optional (customizable to customer requirements) | |
| 11 | Grounding Bar | 2 | Set | ||
| 12 | Accessories | Installation accessories | 1 | Set | Standard |
Base-station equipment and battery projects requiring separate cabinet areas, including exposed roadside and rooftop installations.
The source identifies IP55 or higher protection. Climate, humidity, solar load and component operating limits must be considered in the final thermal design.
Buyer Questions
Answers specific to Outdoor Weatherproof Thermostatic Cabinet selection, configuration and purchasing.
They are source-listed internal dimensions per cabinet. Request the external assembled drawing and base layout.
The temperature target must be specified and checked against heat load, cooling capacity and ambient conditions for the selected configuration.
An emergency fan is listed as an option. Agree its power source, activation conditions and monitored alarms in the controls schedule.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
House communications, power and battery equipment in a serviceable outdoor enclosure.
Protect distributed equipment while maintaining cable entry and service access.
Coordinate cabinet capacity, thermal management and equipment zoning.
Fit protected infrastructure into space-constrained or visually sensitive locations.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.