Telecom base stations
House communications, power and battery equipment in a serviceable outdoor enclosure.
A 27U insulated floor-standing enclosure with 19-inch rails, selectable service doors and fan or 600 W compressor cooling for outdoor communications equipment layouts.
19-inch rails are enclosed by a double-layer structure with 20 mm EPS insulation. HJ-OFVD27 fan versions use two AC220 V top fans; HJ-OFAD27 versions list a 600 W AC220 V air conditioner. Front/rear and front-only door arrangements are described.
Lighting, three-point locking and an example AC distribution unit are listed. The shelf value of 50 kg applies to the shelf rather than the complete equipped cabinet.
The 27U Outdoor Floor-Standing Integrated Cabinet offers a taller rack envelope for sites needing more equipment space in a 650 mm wide configuration. It can organize communications equipment alongside the selected distribution and monitoring functions.
The source lists 1500 × 650 × 650 mm dimensions with a 100 mm base notation. Obtain the dimensioned drawing for base fixings, external projections and cable-entry placement.
Huijue Group can assess OEM or private-label 27U production and changes derived from reference samples or customer drawings. Engineering feasibility, tooling, electrical and enclosure tests, order quantities and delivery scope must be confirmed.
Provide the 27U elevation, equipment depth and weight, heat output, access plan, AC circuits and installation drawings.
| Product Model | HJ-OFVD27-01 | HJ-OFAD27-01 | HJ-OFVD27-02 | HJ-OFAD27-02 |
|---|---|---|---|---|
| Rack Capacity | 27U, 19″ rails | |||
| Thermal Control | AC220V fan type (2 units/set on top) | AC220V 600W air-conditioner type | AC220V fan type (2 units/set on top) | AC220V 600W air-conditioner type |
| Dimensions (H×W×D mm) | 1500-650-650(100mm base) | 1500-650-650(100mm base) | 1500-650-650(100mm base) | 1500-650-650(100mm base) |
| Main Configuration | Double-layer 20 mm EPS structure, front and rear doors | Double-layer 20 mm EPS structure, front door | ||
| Lighting | AC220V, 5 W LED lamp, with door switch | |||
| Shelf | 1.2 mm cold-rolled steel sheet, load capacity 50 kg | |||
| L-shaped Bracket | 1.5 mm cold-rolled steel sheet | |||
| Base | 1.5 mm thick | |||
| Lock | Anti-theft design, outdoor waterproof type, zinc alloy, three-point locking | |||
| Power Distribution Unit | AC circuit breakers: input 32A/2P×1, output 10A/1P×3, SPD 40 kA×1 | |||
| Packaging | Carton + wooden pallet |
Review ambient heat, solar load, humidity and the maintenance environment for the chosen thermal variant. The record supplies no fixed enclosure ingress rating.
Buyer Questions
Answers specific to 27U Outdoor Floor-Standing Integrated Cabinet selection, configuration and purchasing.
The source lists top fans for HJ-OFVD27 and 600 W compressor cooling for HJ-OFAD27. Select from the equipment thermal requirements.
The table identifies a 100 mm base alongside the overall dimensions. Confirm the drawing datum before planning support elevations.
Check cooling clearance, rear connectors, cable routes and servicing needs first. Front access alone does not establish zero rear clearance.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
House communications, power and battery equipment in a serviceable outdoor enclosure.
Protect distributed equipment while maintaining cable entry and service access.
Coordinate cabinet capacity, thermal management and equipment zoning.
Fit protected infrastructure into space-constrained or visually sensitive locations.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.