Telecom base stations
House communications, power and battery equipment in a serviceable outdoor enclosure.
A 32U insulated outdoor rack cabinet with configurable fan or 1500 W air-conditioning thermal control and source-listed power, battery and monitoring options for integrated site equipment.
The 32U Outdoor Floor-Standing Integrated Cabinet combines a 19-inch equipment envelope with support-system choices for communications sites. The larger 750 mm width and depth give the project a defined starting point for arranging equipment, cabling and backup power.
The listed cabinet dimensions are 1750 × 750 × 750 mm with a 150 mm base notation. Final rail depth, service access and support fixings should be confirmed from the selected variant drawing.
Agree the actual bill of materials before allocating customer rack space. Rectifier, UPS and battery values describe support-system choices; their simultaneous inclusion and interfaces need confirmation. Calculate cooling from equipment and power-conversion heat, then check emergency-fan behavior.
Huijue Group can evaluate OEM 32U systems, private-label enclosures and drawing- or sample-based integration. Engineering feasibility, tooling, power and thermal tests, quantity and delivery scope require confirmation.
| Product Model | HJ-OFVD32-01 | HJ-OFAD32-01 | HJ-OFVD32-02 | HJ-OFAD32-02 |
|---|---|---|---|---|
| Rack Capacity | 32U, 19″ rails | |||
| Thermal Control | AC220V fan type (4 units/set on top) | AC220V 1500W air-conditioner type, with emergency fan | AC220V fan type (4 units/set on top) | AC220V 1500W air-conditioner type, with emergency fan |
| Dimensions (H×W×D mm) | 1750-750-750(150mm base) | 1750-750-750(150mm base) | 1750-750-750(150mm base) | 1750-750-750(150mm base) |
| Main Configuration | Double-layer 20 mm EPS structure, front and rear doors | Double-layer 20 mm EPS structure, front door | ||
| Lighting | AC220V, 5 W LED lamp, with door switch | |||
| Shelf | 1.2 mm cold-rolled steel sheet, load capacity 50 kg | |||
| L-shaped Bracket | 1.5 mm cold-rolled steel sheet | |||
| Base | 1.5 mm thick | |||
| Lock | Anti-theft design, outdoor waterproof type, zinc alloy, three-point locking | |||
| Power Distribution Unit | AC circuit breakers: input 32A/2P×1, output 10A/1P×3, SPD 40 kA×1 | |||
| AC-DC Power Supply | Switching power supply, 150 A rectifier | |||
| UPS | 1~6KVA | |||
| Battery System | LiFePO4 battery 100AH, DC48V | |||
| Monitoring Unit | 1. Supports smoke, door contact, water leak, infrared and other sensors; environmental data viewable via connected platform; standard 1U rack mount; 2. Software for viewing collected data and alarms | |||
| Packaging | Carton + wooden pallet |
Integrated outdoor communications nodes and base-station support sites requiring rack equipment with local power and battery functions.
Specify climate and contamination conditions for the selected thermal package. The available record does not assign a fixed ingress rating to this 32U product.
Buyer Questions
Answers specific to 32U Outdoor Floor-Standing Integrated Cabinet selection, configuration and purchasing.
The rail capacity is 32U. Show any rectifier, UPS, PDU and monitoring modules in the layout to establish remaining customer space.
No. Autonomy depends on load, battery configuration, usable capacity and conversion losses. Provide the operating requirement for sizing.
An emergency fan is listed for the air-conditioned variant. Confirm its supply, start conditions and alarms in the control design.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
House communications, power and battery equipment in a serviceable outdoor enclosure.
Protect distributed equipment while maintaining cable entry and service access.
Coordinate cabinet capacity, thermal management and equipment zoning.
Fit protected infrastructure into space-constrained or visually sensitive locations.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.