32U Outdoor Floor-Standing Integrated Cabinet

32U Outdoor Floor-Standing Integrated Cabinet

A 32U insulated outdoor rack cabinet with configurable fan or 1500 W air-conditioning thermal control and source-listed power, battery and monitoring options for integrated site equipment.

Product Features

  • Double-layer enclosure with 20 mm EPS insulation.
  • Fan variant with four top fans or AC220 V 1500 W air-conditioning variant with emergency fan.
  • Front/rear and front-only access versions.
  • Source-listed support equipment includes a 150 A rectifier, 1–6 kVA UPS and DC48 V, 100 Ah LiFePO4 battery arrangement.
  • 1U monitoring options for smoke, door, water-leak and infrared signals.

The 32U Outdoor Floor-Standing Integrated Cabinet combines a 19-inch equipment envelope with support-system choices for communications sites. The larger 750 mm width and depth give the project a defined starting point for arranging equipment, cabling and backup power.

The listed cabinet dimensions are 1750 × 750 × 750 mm with a 150 mm base notation. Final rail depth, service access and support fixings should be confirmed from the selected variant drawing.

Selection & Configuration

Agree the actual bill of materials before allocating customer rack space. Rectifier, UPS and battery values describe support-system choices; their simultaneous inclusion and interfaces need confirmation. Calculate cooling from equipment and power-conversion heat, then check emergency-fan behavior.

Manufacturing & Customization

Huijue Group can evaluate OEM 32U systems, private-label enclosures and drawing- or sample-based integration. Engineering feasibility, tooling, power and thermal tests, quantity and delivery scope require confirmation.

Information for an Accurate Quotation

  • Equipment elevation and continuous/peak load
  • Required rectifier, UPS and battery scope
  • Heat load, alarm interfaces and access clearances

Technical Parameters

Product ModelHJ-OFVD32-01HJ-OFAD32-01HJ-OFVD32-02HJ-OFAD32-02
Rack Capacity32U, 19″ rails
Thermal ControlAC220V fan type (4 units/set on top)AC220V 1500W air-conditioner type, with emergency fanAC220V fan type (4 units/set on top)AC220V 1500W air-conditioner type, with emergency fan
Dimensions (H×W×D mm)1750-750-750(150mm base)1750-750-750(150mm base)1750-750-750(150mm base)1750-750-750(150mm base)
Main ConfigurationDouble-layer 20 mm EPS structure, front and rear doorsDouble-layer 20 mm EPS structure, front door
LightingAC220V, 5 W LED lamp, with door switch
Shelf1.2 mm cold-rolled steel sheet, load capacity 50 kg
L-shaped Bracket1.5 mm cold-rolled steel sheet
Base1.5 mm thick
LockAnti-theft design, outdoor waterproof type, zinc alloy, three-point locking
Power Distribution UnitAC circuit breakers: input 32A/2P×1, output 10A/1P×3, SPD 40 kA×1
AC-DC Power SupplySwitching power supply, 150 A rectifier
UPS1~6KVA
Battery SystemLiFePO4 battery 100AH, DC48V
Monitoring Unit1. Supports smoke, door contact, water leak, infrared and other sensors; environmental data viewable via connected platform; standard 1U rack mount; 2. Software for viewing collected data and alarms
PackagingCarton + wooden pallet

Applications

Integrated outdoor communications nodes and base-station support sites requiring rack equipment with local power and battery functions.

Installation Notes

Specify climate and contamination conditions for the selected thermal package. The available record does not assign a fixed ingress rating to this 32U product.

Buyer Questions

Frequently Asked Questions

Answers specific to 32U Outdoor Floor-Standing Integrated Cabinet selection, configuration and purchasing.

Does the 32U capacity include power-system modules?

The rail capacity is 32U. Show any rectifier, UPS, PDU and monitoring modules in the layout to establish remaining customer space.

Does a 100 Ah battery specify backup duration?

No. Autonomy depends on load, battery configuration, usable capacity and conversion losses. Provide the operating requirement for sizing.

What happens if air conditioning loses power?

An emergency fan is listed for the air-conditioned variant. Confirm its supply, start conditions and alarms in the control design.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Telecom base stations

House communications, power and battery equipment in a serviceable outdoor enclosure.

Roadside and transport sites

Protect distributed equipment while maintaining cable entry and service access.

Edge-computing nodes

Coordinate cabinet capacity, thermal management and equipment zoning.

Underground and concealed sites

Fit protected infrastructure into space-constrained or visually sensitive locations.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.