Rack Fan Cooling Module

Rack Fan Cooling Module

A two- or four-fan cabinet exhaust module using 12038 fans, with thermostat or rotary-switch options for coordinating airflow through network and telecom enclosures.

Product Features

  • Two-fan and four-fan arrangements using 12038 fans.
  • Cold-rolled steel mounting plate with screw-fixed installation.
  • Interfaces described for 600 mm and 800 mm wide cabinets.
  • Optional thermostat and rotary-switch control.
  • Removal and installation through the bolted mounting arrangement.

Rack Fan Cooling Module provides forced exhaust airflow for an equipment cabinet. A steel mounting plate carries the fan set and selected controls, giving the cabinet designer a defined fan assembly to coordinate with air inlets and the internal equipment layout.

Exhaust ventilation exchanges cabinet air with its surroundings. Its effect depends on room temperature, available inlet area and equipment heat, so fan quantity should be chosen through a thermal review rather than assumed to represent a fixed cooling capacity.

Selection & Configuration

Provide the cabinet top opening, hole pattern and width. Confirm supply voltage, connector, required airflow and the complete air path before selecting two or four fans. Agree thermostat setpoint, control behavior, noise target and whether a fan failure must be detected or tolerated.

Manufacturing & Customization

Huijue Group can assess OEM fan plates, private-label assemblies and sample- or drawing-based mounting interfaces. Fan selection, controls, tooling, electrical and thermal tests, quantity and delivery scope require engineering confirmation.

Information for an Accurate Quotation

Send cabinet width, opening drawing, heat load, airflow requirement, fan count, supply voltage, control method, noise and redundancy requirements, connector and quantity.

Technical Parameters

Fan options2 × 12038 / 4 × 12038
Cabinet width600 mm / 800 mm
Control optionsThermostat / rotary switch
Operating temperature-5°C to 55°C
Storage temperature-20°C to 55°C
Atmospheric pressure65–110 kPa

Applications

For network, server and telecom cabinets, indoor distribution enclosures and other suitable cabinets requiring forced top exhaust.

Installation Notes

The operating range is listed as -5°C to 55°C and storage as -20°C to 55°C. Install within an appropriate cabinet environment and check the limits of the selected fans and controls.

Buyer Questions

Frequently Asked Questions

Answers specific to Rack Fan Cooling Module selection, configuration and purchasing.

Does four fans guarantee enough cooling?

No. Confirm airflow and pressure conditions against the actual heat load, room temperature and inlet/exhaust route. Fan count alone is insufficient.

Which supply voltage should be ordered?

This record does not establish a universal voltage. State the available supply and required electrical interface for the proposed fan module.

Will it fit any 600 mm cabinet?

Cabinet width is only a starting reference. Compare the top opening, fixing holes, plate dimensions and clearances with the cabinet drawing.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Equipment rooms

Organize racks, pathways and service access around active network equipment.

Data centers

Coordinate cabinet capacity, cable routes, airflow and planned expansion.

Edge facilities

Package network equipment within compact distributed infrastructure sites.

Retrofit projects

Add capacity while accounting for existing racks, routes and maintenance space.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.