Equipment rooms
Organize racks, pathways and service access around active network equipment.
An open aluminum-alloy wiring support with width and profile-thickness variants for arranging optical, data and communications cables through indoor equipment rooms.
L1-Series Aluminum Cable Runway organizes the cable paths entering and leaving communications equipment. Its open arrangement allows cables to be placed and fixed along a planned route while keeping their positions visible during maintenance.
The source table distinguishes variants by width and material thickness. This is relevant when preparing a cable-support bill of materials: two routes with the same external width may use different profiles and should not be treated as an identical structural assembly.
Select the model by profile thickness as well as route width. Provide actual cable load and support positions for structural assessment. At room entries and rack drops, coordinate the route with cable bend limits, strain relief and the space needed to install additional cables.
Huijue Group can review wiring-rack drawings or samples for OEM manufacture and private-label packages. Nonstandard profile or support details need engineering confirmation, including tooling, load verification, quantity and delivery scope.
Send route widths, required profile thickness, run lengths, cable mass, hanger spacing, layer arrangement, equipment drops and the ceiling, wall or floor fixing details.
| S/N | Model | NAME | Type | Application scenarios | Width (mm) | Cross-sectional dimension (mm) | Thickness (mm) |
|---|---|---|---|---|---|---|---|
| 1 | HJ ZXJ21-L1A3 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 300 | 31*45 | 6.0 |
| 2 | HJ ZXJ21-L1A4 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 400 | 31*45 | 6.0 |
| 3 | HJ ZXJ21-L1A6 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 600 | 31*45 | 6.0 |
| 4 | HJ ZXJ21-L1A8 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 800 | 31*45 | 6.0 |
| 5 | HJ ZXJ21-L1B3 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 300 | 31*45 | 5.4 |
| 6 | HJ ZXJ21-L1B4 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 400 | 31*45 | 5.4 |
| 7 | HJ ZXJ21-L1B6 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 600 | 31*45 | 5.4 |
| 8 | HJ ZXJ21-L1B8 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 800 | 31*45 | 5.4 |
| 9 | HJ ZXJ21-L1C3 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 300 | 31*45 | 5.0 |
| 10 | HJ ZXJ21-L1C4 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 400 | 31*45 | 5.0 |
| 11 | HJ ZXJ21-L1C6 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 600 | 31*45 | 5.0 |
| 12 | HJ ZXJ21-L1C8 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 800 | 31*45 | 5.0 |
| 13 | HJ ZXJ21-L1D3 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 300 | 31*45 | 4.5 |
| 14 | HJ ZXJ21-L1D4 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 400 | 31*45 | 4.5 |
| 15 | HJ ZXJ21-L1D6 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 600 | 31*45 | 4.5 |
| 16 | HJ ZXJ21-L1D8 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 800 | 31*45 | 4.5 |
| 17 | HJ ZXJ21-L1E3 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 300 | 31*45 | 4.3 |
| 18 | HJ ZXJ21-L1E4 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 400 | 31*45 | 4.3 |
| 19 | HJ ZXJ21-L1E6 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 600 | 31*45 | 4.3 |
| 20 | HJ ZXJ21-L1E8 | L1-Series Aluminum Cable Runway | Single-Tier | (indoor) | 800 | 31*45 | 4.3 |
| 21 | HJ ZXJ22-L1F3 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 300 | 31*45 | 6.0 |
| 22 | HJ ZXJ22-L1F4 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 400 | 31*45 | 6.0 |
| 23 | HJ ZXJ22-L1F6 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 600 | 31*45 | 6.0 |
| 24 | HJ ZXJ22-L1F8 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 800 | 31*45 | 6.0 |
| 25 | HJ ZXJ22-L1G3 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 300 | 31*45 | 5.4 |
| 26 | HJ ZXJ22-L1G4 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 400 | 31*45 | 5.4 |
| 27 | HJ ZXJ22-L1G6 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 600 | 31*45 | 5.4 |
| 28 | HJ ZXJ22-L1G8 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 800 | 31*45 | 5.4 |
| 29 | HJ ZXJ22-L1H3 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 300 | 31*45 | 5.0 |
| 30 | HJ ZXJ22-L1H4 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 400 | 31*45 | 5.0 |
| 31 | HJ ZXJ22-L1H6 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 600 | 31*45 | 5.0 |
| 32 | HJ ZXJ22-L1H8 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 800 | 31*45 | 5.0 |
| 33 | HJ ZXJ22-L1K3 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 300 | 31*45 | 4.5 |
| 34 | HJ ZXJ22-L1K4 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 400 | 31*45 | 4.5 |
| 35 | HJ ZXJ22-L1K6 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 600 | 31*45 | 4.5 |
| 36 | HJ ZXJ22-L1K8 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 800 | 31*45 | 4.5 |
| 37 | HJ ZXJ22-L1L3 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 300 | 31*45 | 4.3 |
| 38 | HJ ZXJ22-L1L4 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 400 | 31*45 | 4.3 |
| 39 | HJ ZXJ22-L1L6 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 600 | 31*45 | 4.3 |
| 40 | HJ ZXJ22-L1L8 | L1-Series Aluminum Cable Runway | Double-Tier | (indoor) | 800 | 31*45 | 4.3 |
| S/N | Name | unit | quantity | REMARK | |||
| 1 | Longitudinal Rail | m | 2 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | |||
| 2 | Cross Member | Cables | 4 | The length is the width of the cable runway, and the interval is 250mm. | |||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | |||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | |||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | |||
| S/N | Name | unit | quantity | REMARK | |||
| 1 | Longitudinal Rail | m | 4 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | |||
| 2 | Cross Member | Cables | 8 | The length is the width of the cable runway, and the interval is 250mm. | |||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | |||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | |||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | |||
| 6 | Inter-Tier Support Posts | Cables | 1.33 | Length is double interval, double interval column height ≥ 250mm |
The listed table identifies indoor use. Explain any unusual room moisture, chemical exposure or mixed-metal interfaces during selection.
Buyer Questions
Answers specific to L1-Series Aluminum Cable Runway selection, configuration and purchasing.
The source lists different thickness variants under the same general wiring-rack family. Width alone does not identify the required profile.
This record provides profile dimensions and thickness options. Confirm the allowable loading and support spacing for the selected assembly and route.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
Organize racks, pathways and service access around active network equipment.
Coordinate cabinet capacity, cable routes, airflow and planned expansion.
Package network equipment within compact distributed infrastructure sites.
Add capacity while accounting for existing racks, routes and maintenance space.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.