U2-Series U-Channel Steel Cable Runway

U2-Series U-Channel Steel Cable Runway

An open U-channel steel cable runway with indoor and outdoor finish variants for routing jumpers, optical cables and other communications-room wiring.

Product Features

  • Documented widths of 300, 400, 600 and 800 mm.
  • Hot-dip-galvanized variants for outdoor applications.
  • Electrolytic zinc-coated variants for indoor applications.
  • Open cable placement and fixing access.

U2-Series U-Channel Steel Cable Runway provides a support path for jumper wires and other cables around communications equipment. Its open construction keeps the route accessible for fixing cables, tracing connections and managing later additions.

The table identifies a U2-series steel frame family. Because similar route supports are listed elsewhere in this category, the required model, width and finish should all appear in the project schedule.

Selection & Configuration

Establish the bridge width from cable quantity and spare capacity, then provide the route length, load per metre and proposed support spacing. Specify whether the route is indoor, sheltered or exposed so the finish can be selected from the correct application group. Detail bends and rack transitions rather than assuming straight sections cover the whole route.

Manufacturing & Customization

A U2-series route drawing or sample can be assessed by Huijue Group for OEM production, private labeling and project fittings. Structural details, finish processing, tooling, tests, quantities and delivery scope remain subject to engineering confirmation.

Information for an Accurate Quotation

Include U2-series identification, route geometry, width, cable loading, support spans, installation exposure, bonding and fixing/accessory requirements.

Technical Parameters

S/NModelNAMETypeWidth (mm)Application scenariossurface treatment
1HJ ZXJ11-U2A3U2-Series U-Channel Steel Cable RunwaySingle-Tier300OutdoorHot-Dip Galvanized
2HJ ZXJ11-U2A4U2-Series U-Channel Steel Cable RunwaySingle-Tier400OutdoorHot-Dip Galvanized
3HJ ZXJ11-U2A6U2-Series U-Channel Steel Cable RunwaySingle-Tier600OutdoorHot-Dip Galvanized
4HJ ZXJ11-U2A8U2-Series U-Channel Steel Cable RunwaySingle-Tier800OutdoorHot-Dip Galvanized
5HJ ZXJ21-U2B3U2-Series U-Channel Steel Cable RunwaySingle-Tier300(indoor)Electrolytic zinc-coated
6HJ ZXJ21-U2B4U2-Series U-Channel Steel Cable RunwaySingle-Tier400(indoor)Electrolytic zinc-coated
7HJ ZXJ21-U2B6U2-Series U-Channel Steel Cable RunwaySingle-Tier600(indoor)Electrolytic zinc-coated
8HJ ZXJ21-U2B8U2-Series U-Channel Steel Cable RunwaySingle-Tier800(indoor)Electrolytic zinc-coated
9HJ ZXJ21-U2C3U2-Series U-Channel Steel Cable RunwaySingle-Tier300(indoor)Electrostatic spraying
10HJ ZXJ21-U2C4U2-Series U-Channel Steel Cable RunwaySingle-Tier400(indoor)Electrostatic spraying
11HJ ZXJ21-U2C6U2-Series U-Channel Steel Cable RunwaySingle-Tier600(indoor)Electrostatic spraying
12HJ ZXJ21-U2C8U2-Series U-Channel Steel Cable RunwaySingle-Tier800(indoor)Electrostatic spraying
13HJ ZXJ12-U2D3U2-Series U-Channel Steel Cable RunwayDouble-Tier300OutdoorHot-Dip Galvanized
14HJ ZXJ12-U2D4U2-Series U-Channel Steel Cable RunwayDouble-Tier400OutdoorHot-Dip Galvanized
15HJ ZXJ12-U2D6U2-Series U-Channel Steel Cable RunwayDouble-Tier600OutdoorHot-Dip Galvanized
16HJ ZXJ12-U2D8U2-Series U-Channel Steel Cable RunwayDouble-Tier800OutdoorHot-Dip Galvanized
17HJ ZXJ22-U2E3U2-Series U-Channel Steel Cable RunwayDouble-Tier300(indoor)Electrolytic zinc-coated
18HJ ZXJ22-U2E4U2-Series U-Channel Steel Cable RunwayDouble-Tier400(indoor)Electrolytic zinc-coated
19HJ ZXJ22-U2E6U2-Series U-Channel Steel Cable RunwayDouble-Tier600(indoor)Electrolytic zinc-coated
20HJ ZXJ22-U2E8U2-Series U-Channel Steel Cable RunwayDouble-Tier800(indoor)Electrolytic zinc-coated
21HJ ZXJ22-U2F3U2-Series U-Channel Steel Cable RunwayDouble-Tier300(indoor)Electrostatic spraying
22HJ ZXJ22-U2F4U2-Series U-Channel Steel Cable RunwayDouble-Tier400(indoor)Electrostatic spraying
23HJ ZXJ22-U2F6U2-Series U-Channel Steel Cable RunwayDouble-Tier600(indoor)Electrostatic spraying
24HJ ZXJ22-U2F8U2-Series U-Channel Steel Cable RunwayDouble-Tier800(indoor)Electrostatic spraying
S/NNameunitquantityREMARK
1Longitudinal Railm2When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail
2Cross MemberCables4The length is the width of the cable runway, and the interval is 250mm.
3pieceNumber of places0.1Ground support, the length meets the height of the machine room
4HangingNumber of places0.67Length meets machine room height
5Installation AccessoriesSleeve1Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack
S/NNameunitquantityREMARK
1Longitudinal Railm4When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail
2Cross MemberCables8The length is the width of the cable runway, and the interval is 250mm.
3pieceNumber of places0.1Ground support, the length meets the height of the machine room
4HangingNumber of places0.67Length meets machine room height
5Installation AccessoriesSleeve1Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack
6Inter-Tier Support PostsCables1.33Length is double interval, double interval column height ≥ 250mm

Applications

Relevant uses include communications-room jumper routes and indoor or outdoor cable-support runs with a specified matching finish.

Installation Notes

The source separates outdoor hot-dip-galvanized and indoor electrolytic zinc-coated variants. Confirm exposure and required coating requirements; the finish designation alone does not establish a service life.

Buyer Questions

Frequently Asked Questions

Answers specific to U2-Series U-Channel Steel Cable Runway selection, configuration and purchasing.

Which finish is listed for outdoor variants?

The outdoor models use hot-dip galvanizing. Confirm coating details and the actual exposure conditions for the selected order.

Is this cable runway interchangeable with the U1-series cable runway?

The source assigns different model families. Compare profile, connection and support drawings before treating them as interchangeable.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Equipment rooms

Organize racks, pathways and service access around active network equipment.

Data centers

Coordinate cabinet capacity, cable routes, airflow and planned expansion.

Edge facilities

Package network equipment within compact distributed infrastructure sites.

Retrofit projects

Add capacity while accounting for existing racks, routes and maintenance space.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.