Equipment rooms
Organize racks, pathways and service access around active network equipment.
An open U-channel steel cable runway with indoor and outdoor finish variants for routing jumpers, optical cables and other communications-room wiring.
U2-Series U-Channel Steel Cable Runway provides a support path for jumper wires and other cables around communications equipment. Its open construction keeps the route accessible for fixing cables, tracing connections and managing later additions.
The table identifies a U2-series steel frame family. Because similar route supports are listed elsewhere in this category, the required model, width and finish should all appear in the project schedule.
Establish the bridge width from cable quantity and spare capacity, then provide the route length, load per metre and proposed support spacing. Specify whether the route is indoor, sheltered or exposed so the finish can be selected from the correct application group. Detail bends and rack transitions rather than assuming straight sections cover the whole route.
A U2-series route drawing or sample can be assessed by Huijue Group for OEM production, private labeling and project fittings. Structural details, finish processing, tooling, tests, quantities and delivery scope remain subject to engineering confirmation.
Include U2-series identification, route geometry, width, cable loading, support spans, installation exposure, bonding and fixing/accessory requirements.
| S/N | Model | NAME | Type | Width (mm) | Application scenarios | surface treatment |
|---|---|---|---|---|---|---|
| 1 | HJ ZXJ11-U2A3 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 300 | Outdoor | Hot-Dip Galvanized |
| 2 | HJ ZXJ11-U2A4 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 400 | Outdoor | Hot-Dip Galvanized |
| 3 | HJ ZXJ11-U2A6 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 600 | Outdoor | Hot-Dip Galvanized |
| 4 | HJ ZXJ11-U2A8 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 800 | Outdoor | Hot-Dip Galvanized |
| 5 | HJ ZXJ21-U2B3 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 300 | (indoor) | Electrolytic zinc-coated |
| 6 | HJ ZXJ21-U2B4 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 400 | (indoor) | Electrolytic zinc-coated |
| 7 | HJ ZXJ21-U2B6 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 600 | (indoor) | Electrolytic zinc-coated |
| 8 | HJ ZXJ21-U2B8 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 800 | (indoor) | Electrolytic zinc-coated |
| 9 | HJ ZXJ21-U2C3 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 300 | (indoor) | Electrostatic spraying |
| 10 | HJ ZXJ21-U2C4 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 400 | (indoor) | Electrostatic spraying |
| 11 | HJ ZXJ21-U2C6 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 600 | (indoor) | Electrostatic spraying |
| 12 | HJ ZXJ21-U2C8 | U2-Series U-Channel Steel Cable Runway | Single-Tier | 800 | (indoor) | Electrostatic spraying |
| 13 | HJ ZXJ12-U2D3 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 300 | Outdoor | Hot-Dip Galvanized |
| 14 | HJ ZXJ12-U2D4 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 400 | Outdoor | Hot-Dip Galvanized |
| 15 | HJ ZXJ12-U2D6 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 600 | Outdoor | Hot-Dip Galvanized |
| 16 | HJ ZXJ12-U2D8 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 800 | Outdoor | Hot-Dip Galvanized |
| 17 | HJ ZXJ22-U2E3 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 300 | (indoor) | Electrolytic zinc-coated |
| 18 | HJ ZXJ22-U2E4 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 400 | (indoor) | Electrolytic zinc-coated |
| 19 | HJ ZXJ22-U2E6 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 600 | (indoor) | Electrolytic zinc-coated |
| 20 | HJ ZXJ22-U2E8 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 800 | (indoor) | Electrolytic zinc-coated |
| 21 | HJ ZXJ22-U2F3 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 300 | (indoor) | Electrostatic spraying |
| 22 | HJ ZXJ22-U2F4 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 400 | (indoor) | Electrostatic spraying |
| 23 | HJ ZXJ22-U2F6 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 600 | (indoor) | Electrostatic spraying |
| 24 | HJ ZXJ22-U2F8 | U2-Series U-Channel Steel Cable Runway | Double-Tier | 800 | (indoor) | Electrostatic spraying |
| S/N | Name | unit | quantity | REMARK | ||
| 1 | Longitudinal Rail | m | 2 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | ||
| 2 | Cross Member | Cables | 4 | The length is the width of the cable runway, and the interval is 250mm. | ||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | ||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | ||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | ||
| S/N | Name | unit | quantity | REMARK | ||
| 1 | Longitudinal Rail | m | 4 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | ||
| 2 | Cross Member | Cables | 8 | The length is the width of the cable runway, and the interval is 250mm. | ||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | ||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | ||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | ||
| 6 | Inter-Tier Support Posts | Cables | 1.33 | Length is double interval, double interval column height ≥ 250mm |
Relevant uses include communications-room jumper routes and indoor or outdoor cable-support runs with a specified matching finish.
The source separates outdoor hot-dip-galvanized and indoor electrolytic zinc-coated variants. Confirm exposure and required coating requirements; the finish designation alone does not establish a service life.
Buyer Questions
Answers specific to U2-Series U-Channel Steel Cable Runway selection, configuration and purchasing.
The outdoor models use hot-dip galvanizing. Confirm coating details and the actual exposure conditions for the selected order.
The source assigns different model families. Compare profile, connection and support drawings before treating them as interchangeable.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
Organize racks, pathways and service access around active network equipment.
Coordinate cabinet capacity, cable routes, airflow and planned expansion.
Package network equipment within compact distributed infrastructure sites.
Add capacity while accounting for existing racks, routes and maintenance space.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.