27U Outdoor Floor-Standing Integrated Cabinet

27U Outdoor Floor-Standing Integrated Cabinet

A 27U insulated floor-standing enclosure with 19-inch rails, selectable service doors and fan or 600 W compressor cooling for outdoor communications equipment layouts.

Product Features

19-inch rails are enclosed by a double-layer structure with 20 mm EPS insulation. HJ-OFVD27 fan versions use two AC220 V top fans; HJ-OFAD27 versions list a 600 W AC220 V air conditioner. Front/rear and front-only door arrangements are described.

Lighting, three-point locking and an example AC distribution unit are listed. The shelf value of 50 kg applies to the shelf rather than the complete equipped cabinet.

The 27U Outdoor Floor-Standing Integrated Cabinet offers a taller rack envelope for sites needing more equipment space in a 650 mm wide configuration. It can organize communications equipment alongside the selected distribution and monitoring functions.

The source lists 1500 × 650 × 650 mm dimensions with a 100 mm base notation. Obtain the dimensioned drawing for base fixings, external projections and cable-entry placement.

Selection & Configuration

  • Allow space for power modules and wiring within the 27U layout.
  • Check rear connections before choosing a front-only version.
  • Assess cooling with heat dissipation and the desired internal temperature.
  • Review foundation capacity, anchoring and cable entry using the actual loaded mass.

Manufacturing & Customization

Huijue Group can assess OEM or private-label 27U production and changes derived from reference samples or customer drawings. Engineering feasibility, tooling, electrical and enclosure tests, order quantities and delivery scope must be confirmed.

Information for an Accurate Quotation

Provide the 27U elevation, equipment depth and weight, heat output, access plan, AC circuits and installation drawings.

Technical Parameters

Product ModelHJ-OFVD27-01HJ-OFAD27-01HJ-OFVD27-02HJ-OFAD27-02
Rack Capacity27U, 19″ rails
Thermal ControlAC220V fan type (2 units/set on top)AC220V 600W air-conditioner typeAC220V fan type (2 units/set on top)AC220V 600W air-conditioner type
Dimensions (H×W×D mm)1500-650-650(100mm base)1500-650-650(100mm base)1500-650-650(100mm base)1500-650-650(100mm base)
Main ConfigurationDouble-layer 20 mm EPS structure, front and rear doorsDouble-layer 20 mm EPS structure, front door
LightingAC220V, 5 W LED lamp, with door switch
Shelf1.2 mm cold-rolled steel sheet, load capacity 50 kg
L-shaped Bracket1.5 mm cold-rolled steel sheet
Base1.5 mm thick
LockAnti-theft design, outdoor waterproof type, zinc alloy, three-point locking
Power Distribution UnitAC circuit breakers: input 32A/2P×1, output 10A/1P×3, SPD 40 kA×1
PackagingCarton + wooden pallet

Applications

  • Outdoor communications racks
  • Roadside network and monitoring sites
  • Base-station support requiring a medium rack height

Installation Notes

Review ambient heat, solar load, humidity and the maintenance environment for the chosen thermal variant. The record supplies no fixed enclosure ingress rating.

Buyer Questions

Frequently Asked Questions

Answers specific to 27U Outdoor Floor-Standing Integrated Cabinet selection, configuration and purchasing.

What distinguishes the fan and air-conditioned versions?

The source lists top fans for HJ-OFVD27 and 600 W compressor cooling for HJ-OFAD27. Select from the equipment thermal requirements.

Does the height include the base?

The table identifies a 100 mm base alongside the overall dimensions. Confirm the drawing datum before planning support elevations.

Can the front-only cabinet be installed against a wall?

Check cooling clearance, rear connectors, cable routes and servicing needs first. Front access alone does not establish zero rear clearance.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Telecom base stations

House communications, power and battery equipment in a serviceable outdoor enclosure.

Roadside and transport sites

Protect distributed equipment while maintaining cable entry and service access.

Edge-computing nodes

Coordinate cabinet capacity, thermal management and equipment zoning.

Underground and concealed sites

Fit protected infrastructure into space-constrained or visually sensitive locations.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.