Telecom base stations
House communications, power and battery equipment in a serviceable outdoor enclosure.
A single-bay sandwich-panel outdoor cabinet with upper and lower functional areas, a battery rack and configurable cooling, designed for controlled access to communications equipment.
The Outdoor Armored Cabinet, HJ-XDF-X01, houses equipment and battery functions in a single enclosure with upper and lower compartments. Its 1800 × 800 × 800 mm listed configuration suits projects that need a coordinated equipment bay and backup-power area.
The cabinet’s armored designation should be read alongside its stated construction. Any project requiring a particular forced-entry or impact resistance must define the test and acceptance requirements separately.
Check equipment depth, battery weight and battery replacement space within the single bay. Match cooling to the heat load and specify whether the emergency fan, generator inlet, power system and remote monitoring are required. Reserve space for grounding and cable bend radii.
Huijue Group can assess manufacturer OEM builds and private labels, including sample-based cabinet replication or drawing-based compartment changes. Feasibility, tooling, enclosure and thermal tests, quantity and delivery scope require confirmation for each proposal.
Supply rack and battery drawings, desired security criteria, ambient conditions, heat load and optional power/monitoring equipment.
| HJ-XDF-X01 Product Configuration | |||||
|---|---|---|---|---|---|
| No. | Item | Specification | Qty | Unit | Remarks |
| 1 | Sandwich-panel outdoor cabinet (single cabinet) | 1800*800*800 H*W*D | 1 | set | Includes uprights and internal structural parts; provides equipment mounting space, 1 battery rack, 50 mm sandwich-panel construction, upper/lower compartments |
| 2 | Shelves, L-brackets | * | set | Optional (1–6 pcs) | |
| 3 | Air conditioner | Compressor 1500 W | * | set | (Fan, heat exchanger, or air conditioner optional) |
| 4 | Base | 1 | set | ||
| 5 | Emergency fan | * | set | Starts when AC power fails | |
| 6 | Lamp | 1 | pc | ||
| 7 | Power distribution unit | AC, DC | * | set | Optional |
| 8 | Power system | * | set | Optional | |
| Genset inlet | * | set | Optional | ||
| 8 | Battery | * | set | Optional | |
| 9 | Monitoring unit | * | set | Optional (sensors optional) | |
| 10 | Other options | * | set | Optional (customizable to customer requirements) | |
| 11 | Grounding bar assembly | 1 | set | ||
| 12 | Accessories | Installation accessories | 1 | set | Standard |
IP55 or higher protection is source-listed. Verify the complete assembly against local weather, corrosion and the selected electrical equipment limits.
Buyer Questions
Answers specific to Outdoor Armored Cabinet selection, configuration and purchasing.
No universal security certification is stated here. Define the required resistance test and lock specification for engineering review.
The generator inlet is an optional item. Confirm connector type, rating and its relationship to the power-distribution system.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
House communications, power and battery equipment in a serviceable outdoor enclosure.
Protect distributed equipment while maintaining cable entry and service access.
Coordinate cabinet capacity, thermal management and equipment zoning.
Fit protected infrastructure into space-constrained or visually sensitive locations.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.