Cabinet-Type Telecom DC Power System (HJ-DYZ-600)

Cabinet-Type Telecom DC Power System (HJ-DYZ-600)

HJ-DYZ-600 cabinet power system combining AC distribution, modular rectification, battery management and monitored DC feeders for communications equipment rooms.

Product Features

  • Controller settings cover float/equalization voltage and charging-current limits.
  • Functions include temperature compensation, capacity calculation, online battery testing and rectifier sleep management.
  • RS232, RS485 and dry-contact interfaces support supervised equipment-room operation.
  • AC/DC surge protection and fault alarms are included in the described architecture.

The HJ-DYZ-600 cabinet-type telecom DC power system provides a central DC power plant for communications facilities. Its cabinet brings together AC incoming distribution, a monitoring unit, DC distribution and provision for up to twelve rectifier modules. Battery management is part of the system architecture, enabling the plant to coordinate charging and backup operation rather than simply connect batteries across an unmanaged output.

Low-voltage battery protection is documented, with load disconnect available as an option. The final module count, feeder arrangement and battery configuration should follow the room’s present load, recharge requirement and expansion plan.

Selection & Configuration

Check the rectifier population against both running load and battery recovery current, with any redundancy allowance explicitly identified. The documented environmental schedule includes temperature-dependent derating from 55°C to 65°C and altitude corrections above 2000 m. Have engineering confirm the applicable operating limit for the ordered module and site.

Manufacturing & Customization

For room-specific cabinet builds, Huijue Group can assess an approved single-line drawing or reference assembly and OEM/private-label requirements. Busbar layout, module compatibility, cable access, tooling, validation tests, order quantity and the boundary between factory wiring and site installation require engineering confirmation.

Information for an Accurate Quotation

Provide DC load and growth, redundancy policy, battery type/capacity, recharge target, AC incoming service, feeder ratings, alarm point list, ambient temperature and site altitude.

Technical Parameters

Environmental ParametersOperating conditionsTransport conditionsStorage conditionsApplicable standardsRemarks
CategoryParameterUnit
Climatic conditionsTemperatureLow temperature℃-33-40-40YD/T 1058-2000 Clauses 4.1.1 and 4.1.2Full-load start at −40℃; linear 20% derating from +55 to +65℃.
High temperature℃657070
Temperature change℃/min/1/ETS 300 019-2-2 T2.3
Operating ambient temperature℃-33—65Full-load extreme operating temperature
Storage temperature℃-40—70
HumidityRelative humidity%5-9090 (40±2℃)/YD/T 1058-2000 Clause 4.1.3Short-term test: 0—95%, max 95%, non-condensing
CondensationYes/NoNoNoYes
Atmospheric pressureLow pressurekPa867070YD/T 1058-2000 Clause 4.1.4Module testing only
High pressurekPa106106106
Altitudem≤4000Above 2000 m, derate 0.5℃ per additional 100 m

Applications

  • Central power plants in telecom equipment rooms
  • Communications cabinets needing managed battery charging
  • Unattended nodes with remote DC power alarms

Installation Notes

The source lists an operating ambient range of −33°C to 65°C with qualifications on high-temperature loading. Confirm room ventilation, altitude, humidity and cable/service access before final selection.

Buyer Questions

Frequently Asked Questions

Answers specific to Cabinet-Type Telecom DC Power System (HJ-DYZ-600) selection, configuration and purchasing.

Does every HJ-DYZ-600 arrive with twelve rectifiers?

Twelve is the fully configured module provision. The ordered population must be specified from load, battery charging and redundancy requirements.

Can charging settings be matched to the room battery bank?

Float, equalization and current-limit settings are adjustable through the controller or a reviewed remote system. Battery manufacturer limits and temperature compensation must be checked during commissioning.

Can the full rating be used at 65°C?

The source specifies high-temperature derating between 55°C and 65°C. Engineering must confirm the usable current under the actual thermal and altitude conditions.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Core equipment rooms

Coordinate DC power, distribution, batteries and monitoring around communications loads.

Compact telecom sites

Use integrated or wall-mounted systems where equipment space is limited.

Outdoor base stations

Match generation, storage and power conversion to load and autonomy requirements.

Hybrid and off-grid nodes

Combine grid, solar, battery or generator inputs around a defined operating strategy.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.