Equipment rooms
Organize racks, pathways and service access around active network equipment.
A U1-series open steel cable-support frame with documented route widths and environment-specific finishes for orderly communications infrastructure wiring installations.
The listed widths are 300, 400, 600 and 800 mm. Outdoor models are hot-dip galvanized, while indoor models include electrolytic zinc-coated construction. An open frame allows cable placement and visual route inspection without enclosing the cable bundle.
The U1-Series U-Channel Steel Cable Runway supports optical, data and other cables entering or leaving communications equipment. Its open structure keeps the cable route accessible for installation and maintenance.
This product uses U1-series identification in the source table. Match that family to the installation drawing and accessory list so that sections, supports and connectors are selected as a coherent assembly.
Obtain a load and support assessment for the actual route. The product name does not establish a pedestrian load rating.
Huijue Group can review U-shaped frames from an OEM specification, private-label brief, sample or dimensioned route drawing. Profile changes, joint details and supports require engineering agreement on tooling, verification tests, quantity and delivery scope.
Provide the U1 model family, widths, total lengths, cable loading, span arrangement, supports, coating needs and required fittings.
| S/N | Model | NAME | Type | Width (mm) | Application scenarios | surface treatment |
|---|---|---|---|---|---|---|
| 1 | HJ ZXJ11-U1A3 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 300 | Outdoor | Hot-Dip Galvanized |
| 2 | HJ ZXJ11-U1A4 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 400 | Outdoor | Hot-Dip Galvanized |
| 3 | HJ ZXJ11-U1A6 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 600 | Outdoor | Hot-Dip Galvanized |
| 4 | HJ ZXJ11-U1A8 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 800 | Outdoor | Hot-Dip Galvanized |
| 5 | HJ ZXJ21-U1B3 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 300 | (indoor) | Electrolytic zinc-coated |
| 6 | HJ ZXJ21-U1B4 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 400 | (indoor) | Electrolytic zinc-coated |
| 7 | HJ ZXJ21-U1B6 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 600 | (indoor) | Electrolytic zinc-coated |
| 8 | HJ ZXJ21-U1B8 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 800 | (indoor) | Electrolytic zinc-coated |
| 9 | HJ ZXJ21-U1C3 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 300 | (indoor) | Electrostatic spraying |
| 10 | HJ ZXJ21-U1C4 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 400 | (indoor) | Electrostatic spraying |
| 11 | HJ ZXJ21-U1C6 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 600 | (indoor) | Electrostatic spraying |
| 12 | HJ ZXJ21-U1C8 | U1-Series U-Channel Steel Cable Runway | Single-Tier | 800 | (indoor) | Electrostatic spraying |
| 13 | HJ ZXJ12-U1D3 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 300 | Outdoor | Hot-Dip Galvanized |
| 14 | HJ ZXJ12-U1D4 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 400 | Outdoor | Hot-Dip Galvanized |
| 15 | HJ ZXJ12-U1D6 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 600 | Outdoor | Hot-Dip Galvanized |
| 16 | HJ ZXJ12-U1D8 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 800 | Outdoor | Hot-Dip Galvanized |
| 17 | HJ ZXJ22-U1E3 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 300 | (indoor) | Electrolytic zinc-coated |
| 18 | HJ ZXJ22-U1E4 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 400 | (indoor) | Electrolytic zinc-coated |
| 19 | HJ ZXJ22-U1E6 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 600 | (indoor) | Electrolytic zinc-coated |
| 20 | HJ ZXJ22-U1E8 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 800 | (indoor) | Electrolytic zinc-coated |
| 21 | HJ ZXJ22-U1F3 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 300 | (indoor) | Electrostatic spraying |
| 22 | HJ ZXJ22-U1F4 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 400 | (indoor) | Electrostatic spraying |
| 23 | HJ ZXJ22-U1F6 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 600 | (indoor) | Electrostatic spraying |
| 24 | HJ ZXJ22-U1F8 | U1-Series U-Channel Steel Cable Runway | Double-Tier | 800 | (indoor) | Electrostatic spraying |
| S/N | Name | unit | quantity | REMARK | ||
| 1 | Longitudinal Rail | m | 2 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | ||
| 2 | Cross Member | Cables | 4 | The length is the width of the cable runway, and the interval is 250mm. | ||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | ||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | ||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | ||
| S/N | Name | unit | quantity | REMARK | ||
| 1 | Longitudinal Rail | m | 4 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | ||
| 2 | Cross Member | Cables | 8 | The length is the width of the cable runway, and the interval is 250mm. | ||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | ||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | ||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | ||
| 6 | Inter-Tier Support Posts | Cables | 1.33 | Length is double interval, double interval column height ≥ 250mm |
Choose the finish by exposure. Include moisture, corrosive conditions and any site coating specification in the inquiry rather than assuming all variants share the same environmental suitability.
Buyer Questions
Answers specific to U1-Series U-Channel Steel Cable Runway selection, configuration and purchasing.
The verified description identifies a cable-support frame. No pedestrian loading capability is established by this listing.
The source associates indoor models with electrolytic zinc coating and outdoor models with hot-dip galvanizing. Confirm the precise ordered model and finish.
Provide cable load, profile and connection details, fixing conditions and acceptable deflection. The span should be confirmed for the assembled route.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
Organize racks, pathways and service access around active network equipment.
Coordinate cabinet capacity, cable routes, airflow and planned expansion.
Package network equipment within compact distributed infrastructure sites.
Add capacity while accounting for existing racks, routes and maintenance space.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.