Equipment rooms
Organize racks, pathways and service access around active network equipment.
An angle-steel cable-support family with 300–800 mm widths, single or double levels, and finish variants selected for indoor or outdoor routing.
Widths of 300, 400, 600 and 800 mm are documented. Outdoor versions use hot-dip galvanizing; indoor versions are listed with electrolytic zinc coating or electrostatic spray. The source includes support and accessory schedules for both layer arrangements.
J1-Series Angle-Steel Cable Runway provides an open steel route for cables around communications installations. It supports installation, fixing and organization of the cable bundle without hiding the route inside a closed channel.
The J1-series table identifies single-layer and double-layer versions. Selecting the complete variant matters: the route width, layer arrangement and finish each affect the bill of materials and how the assembly connects to its supports.
Account for reinforcement at wide sections and changes of direction in the assembly design. Obtain the approved span and load arrangement for the final model.
Huijue Group can assess angle-steel frames to an OEM brief or private-label program using samples and project drawings. Nonstandard sections, joints and coatings require engineering confirmation of tooling, test scope, quantity and delivery responsibilities.
Provide J1-series identification, widths, lengths, layer count, loading, support spacing and heights, finish, bends, transitions and bonding details.
| S/N | Model | NAME | Type | Width (mm) | Application scenarios | surface treatment |
|---|---|---|---|---|---|---|
| 1 | HJ ZXJ11-J1A3 | J1-Series Angle-Steel Cable Runway | Single-Tier | 300 | Outdoor | Hot-Dip Galvanized |
| 2 | HJ ZXJ11-J1A4 | J1-Series Angle-Steel Cable Runway | Single-Tier | 400 | Outdoor | Hot-Dip Galvanized |
| 3 | HJ ZXJ11-J1A6 | J1-Series Angle-Steel Cable Runway | Single-Tier | 600 | Outdoor | Hot-Dip Galvanized |
| 4 | HJ ZXJ11-J1A8 | J1-Series Angle-Steel Cable Runway | Single-Tier | 800 | Outdoor | Hot-Dip Galvanized |
| 5 | HJ ZXJ21-J1B3 | J1-Series Angle-Steel Cable Runway | Single-Tier | 300 | (indoor) | Electrolytic zinc-coated |
| 6 | HJ ZXJ21-J1B4 | J1-Series Angle-Steel Cable Runway | Single-Tier | 400 | (indoor) | Electrolytic zinc-coated |
| 7 | HJ ZXJ21-J1B6 | J1-Series Angle-Steel Cable Runway | Single-Tier | 600 | (indoor) | Electrolytic zinc-coated |
| 8 | HJ ZXJ21-J1B8 | J1-Series Angle-Steel Cable Runway | Single-Tier | 800 | (indoor) | Electrolytic zinc-coated |
| 9 | HJ ZXJ21-J1C3 | J1-Series Angle-Steel Cable Runway | Single-Tier | 300 | (indoor) | Electrostatic spraying |
| 10 | HJ ZXJ21-J1C4 | J1-Series Angle-Steel Cable Runway | Single-Tier | 400 | (indoor) | Electrostatic spraying |
| 11 | HJ ZXJ21-J1C6 | J1-Series Angle-Steel Cable Runway | Single-Tier | 600 | (indoor) | Electrostatic spraying |
| 12 | HJ ZXJ21-J1C8 | J1-Series Angle-Steel Cable Runway | Single-Tier | 800 | (indoor) | Electrostatic spraying |
| 13 | HJ ZXJ12-J1D3 | J1-Series Angle-Steel Cable Runway | Double-Tier | 300 | Outdoor | Hot-Dip Galvanized |
| 14 | HJ ZXJ12-J1D4 | J1-Series Angle-Steel Cable Runway | Double-Tier | 400 | Outdoor | Hot-Dip Galvanized |
| 15 | HJ ZXJ12-J1D6 | J1-Series Angle-Steel Cable Runway | Double-Tier | 600 | Outdoor | Hot-Dip Galvanized |
| 16 | HJ ZXJ12-J1D8 | J1-Series Angle-Steel Cable Runway | Double-Tier | 800 | Outdoor | Hot-Dip Galvanized |
| 17 | HJ ZXJ22-J1E3 | J1-Series Angle-Steel Cable Runway | Double-Tier | 300 | (indoor) | Electrolytic zinc-coated |
| 18 | HJ ZXJ22-J1E4 | J1-Series Angle-Steel Cable Runway | Double-Tier | 400 | (indoor) | Electrolytic zinc-coated |
| 19 | HJ ZXJ22-J1E6 | J1-Series Angle-Steel Cable Runway | Double-Tier | 600 | (indoor) | Electrolytic zinc-coated |
| 20 | HJ ZXJ22-J1E8 | J1-Series Angle-Steel Cable Runway | Double-Tier | 800 | (indoor) | Electrolytic zinc-coated |
| 21 | HJ ZXJ22-J1F3 | J1-Series Angle-Steel Cable Runway | Double-Tier | 300 | (indoor) | Electrostatic spraying |
| 22 | HJ ZXJ22-J1F4 | J1-Series Angle-Steel Cable Runway | Double-Tier | 400 | (indoor) | Electrostatic spraying |
| 23 | HJ ZXJ22-J1F6 | J1-Series Angle-Steel Cable Runway | Double-Tier | 600 | (indoor) | Electrostatic spraying |
| 24 | HJ ZXJ22-J1F8 | J1-Series Angle-Steel Cable Runway | Double-Tier | 800 | (indoor) | Electrostatic spraying |
| S/N | Name | unit | quantity | REMARK | ||
| 1 | Longitudinal Rail | m | 2 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | ||
| 2 | Cross Member | Cables | 4 | The length is the width of the cable runway, and the interval is 250mm. | ||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | ||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | ||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | ||
| S/N | Name | unit | quantity | REMARK | ||
| 1 | Longitudinal Rail | m | 4 | When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail | ||
| 2 | Cross Member | Cables | 8 | The length is the width of the cable runway, and the interval is 250mm. | ||
| 3 | piece | Number of places | 0.1 | Ground support, the length meets the height of the machine room | ||
| 4 | Hanging | Number of places | 0.67 | Length meets machine room height | ||
| 5 | Installation Accessories | Sleeve | 1 | Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack | ||
| 6 | Inter-Tier Support Posts | Cables | 1.33 | Length is double interval, double interval column height ≥ 250mm |
Match the listed indoor or outdoor model to the site. Provide corrosion exposure and coating specifications when the route operates beyond a normal indoor room.
Buyer Questions
Answers specific to J1-Series Angle-Steel Cable Runway selection, configuration and purchasing.
Capacity also depends on profile dimensions, span, connections and loading. The assembled route needs a confirmed engineering basis.
The table lists electrolytic zinc coating and electrostatic spray for indoor variants. Specify the required option on the order.
The documented function is cable support. A personnel-access structure would require its own verified design and load rating.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
Organize racks, pathways and service access around active network equipment.
Coordinate cabinet capacity, cable routes, airflow and planned expansion.
Package network equipment within compact distributed infrastructure sites.
Add capacity while accounting for existing racks, routes and maintenance space.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.