Trough-Type Cable Tray

Trough-Type Cable Tray

A trough-style cable route with multiple width, height and thickness options for communications and control wiring where enclosure and access must be considered together.

Product Features

The documented range includes 15, 30, 50 and 100 mm channel heights and several widths between 50 and 600 mm, depending on the row selected. Channel thickness varies from 1.0 to 2.0 mm in the table. Cover availability and thickness are also row-specific.

Trough-Type Cable Tray provides a trough route for communications, computer and control cables. Compared with an open frame, its channel form changes how cables are enclosed, inspected and accessed, making cover selection and service clearances part of the route design.

The source overview describes enclosed routing, while its size table includes shallow variants with no cover specified. Select the actual channel-and-cover combination instead of assuming that every listed size is a fully closed assembly.

Selection & Configuration

  • Identify the required width, height and material thickness together.
  • Specify whether a cover is required and how it will be removed.
  • Check cable loading, support spacing and cable exits.
  • Retain inspection space between parallel routes.

If electromagnetic shielding or corrosion resistance is a project requirement, define measurable criteria and request evidence for the exact material, finish, joints and cover arrangement.

Manufacturing & Customization

Huijue Group can review trough drawings, samples and OEM/private-label requirements. Material, cover details, tooling, validation tests, quantities and delivery scope must be confirmed before a variation is accepted.

Information for an Accurate Quotation

Send cross-section dimensions, channel/cover thickness, material and finish, route geometry, loading, supports, entry details and any shielding or corrosion criteria.

Technical Parameters

S/NModelNAMEHeight (in mm)Width (mm)Groove thickness (mm)Cover thickness (mm)
1HJ CSQJ1-1505ATrough-Type Cable Tray15501N/A
2HJ CSQJ1-1575ATrough-Type Cable Tray15751N/A
3HJ CSQJ1-1510ATrough-Type Cable Tray151001N/A
4HJ CSQJ1-1515ATrough-Type Cable Tray151501N/A
5HJ CSQJ1-1522ATrough-Type Cable Tray152251.2N/A
6HJ CSQJ1-1530ATrough-Type Cable Tray153001.2N/A
7HJ CSQJ1-1545ATrough-Type Cable Tray154501.5N/A
8HJ CSQJ1-1560ATrough-Type Cable Tray156002N/A
9HJ CSQJ1-3005ATrough-Type Cable Tray30501.21
10HJ CSQJ1-3075ATrough-Type Cable Tray30751.21
11HJ CSQJ1-3010ATrough-Type Cable Tray301001.21
12HJ CSQJ1-3015ATrough-Type Cable Tray301501.51
13HJ CSQJ1-3022ATrough-Type Cable Tray302251.51
14HJ CSQJ1-3030ATrough-Type Cable Tray303001.51.2
15HJ CSQJ1-3045ATrough-Type Cable Tray304501.51.5
16HJ CSQJ1-3060ATrough-Type Cable Tray3060021.5
17HJ CSQJ1-3005ATrough-Type Cable Tray50501.21
18HJ CSQJ1-3075ATrough-Type Cable Tray50751.21
19HJ CSQJ1-3010ATrough-Type Cable Tray501001.21
20HJ CSQJ1-3015ATrough-Type Cable Tray501501.51
21HJ CSQJ1-3020ATrough-Type Cable Tray502001.51
22HJ CSQJ1-3022ATrough-Type Cable Tray502251.51
23HJ CSQJ1-3030ATrough-Type Cable Tray503001.51.2
24HJ CSQJ1-3045ATrough-Type Cable Tray504501.51.5
25HJ CSQJ1-3060ATrough-Type Cable Tray5060021.5
26HJ CSQJ1-10010ATrough-Type Cable Tray1001001.51
27HJ CSQJ1-10015ATrough-Type Cable Tray1001501.51
28HJ CSQJ1-10020ATrough-Type Cable Tray1002001.51
29HJ CSQJ1-10030ATrough-Type Cable Tray1003001.51.2
30HJ CSQJ1-10060ATrough-Type Cable Tray10060021.5
31HJ CSQJ1-15015ATrough-Type Cable Tray1501501.51
32HJ CSQJ1-15020ATrough-Type Cable Tray1502001.51
33HJ CSQJ1-15030ATrough-Type Cable Tray1503001.51.2
34HJ CSQJ1-15060ATrough-Type Cable Tray15060021.5

Applications

  • Communications and computer cable routes.
  • Control and instrumentation wiring.
  • Parallel cable runs with planned inspection access.

Installation Notes

State installation exposure and any corrosive conditions. No protection class or shielding performance is established here for every listed trough size.

Buyer Questions

Frequently Asked Questions

Answers specific to Trough-Type Cable Tray selection, configuration and purchasing.

Does every size include a cover?

No. The table identifies some shallow variants with no cover listed. Confirm the channel and cover as separate explicit order details.

Is a shielding performance value available from the name alone?

No. Shielding depends on material, joints, cover continuity and bonding. Provide the required performance criteria for evaluation.

How should parallel trays be spaced?

Allow enough room to open covers, inspect cables and service adjacent routes. Determine the clearance from the actual tray dimensions and room layout.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Equipment rooms

Organize racks, pathways and service access around active network equipment.

Data centers

Coordinate cabinet capacity, cable routes, airflow and planned expansion.

Edge facilities

Package network equipment within compact distributed infrastructure sites.

Retrofit projects

Add capacity while accounting for existing racks, routes and maintenance space.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.