Core equipment rooms
Coordinate DC power, distribution, batteries and monitoring around communications loads.
Wall-mounted switch-mode telecom power families with controller-managed batteries, multiple rectifier sizes and compact configurations for smaller DC plants.
The Wall-Mounted High-Frequency Switch-Mode Power System is a family of compact rectifier assemblies rather than one fixed chassis. The source includes 15 A-, 30 A- and 50 A-module platforms with different system currents and cabinet depths. This allows a smaller DC plant to be matched to mounting space, battery provision and communications load.
A CUC-12H monitoring unit is listed across the configurations. Battery management and online testing support routine maintenance, while soft-switching conversion and active power-factor correction form the documented rectifier design.
Choose the system by usable current, module redundancy and battery space. Source-table rows combine several variants, so obtain a model-specific drawing before fixing anchors or cable entries. Check enclosure dimensions, rectifier type and output rating together; a similar model prefix is insufficient for interchangeability.
Huijue Group can evaluate OEM/private-label wall-mounted systems and sample- or drawing-led layouts. Proposed chassis dimensions, controller interfaces and battery compartments need engineering confirmation of feasibility, tooling, validation tests, quantity and the final supply boundary.
Send required output current, redundancy, battery dimensions, controller interface, incoming AC conditions, mounting space and required protection rating.
| Model | Type No. | Monitoring Module | Dimensions (mm) | ||
|---|---|---|---|---|---|
| DPS3000H-48/50 (300A and below, wall-mounted) | MCS48/300-YQCD-04 | CUC-12H CUC-12H | DPR48/50C DPR48/50C | 300A 200A | 550(W)×280(D)×550(H) 480(W)×270(D)×465(H) |
| ESAB200-NDA00 | |||||
| ESAB150-NDC00 | CUC-12H | DPR48/50C | 150A | 500(W)×280(D)×750(H) (batteries can be built in) | |
| DPS1800G-48/30 (210A and below, wall-mounted) | ESGH210-NDB00 | CUC-12H | DPR48/30H | 210A | 480(W)×270(D)×465(H) |
| ESGH120-NDB00 | CUC-12H CUC-12H | DPR48/30H DPR48/30H | 120A 90A | 480(W)×270(D)×465(H) 500(W)×280(D)×750(H) (batteries can be built in) | |
| ESGH90-NDB00 | |||||
| DPS850-48/15 (60A and below, wall-mounted) | DPS48/45-DBCD | CUC-12H | DPR48/15-D-DGC | 45A | 400(W)×205(D)×280(H) |
| DPS48/45-DQCD | CUC-12H CUC-12H | DPR48/15-D-DGC DPR48/15-D-DGC | 45A 45A | 480(W)×270(D)×600(H) 540(W)×270(D)×600(H) | |
| DPS48/45-DQDD | |||||
| WPS48/15DF (2.55kW,IP45) | ESOA45-MAA01-00 | CUC-12H | DPR48/15-D-DGC | 45A | 540(W)×270(D)×600(H) |
| WPS48/30DF (5.4kW,IP45) | ESOA060-NDB00 | CUC-12H | DPR48/30H | 60A | 480(W)×342(D)×600(H) |
| WPS48/50DE (11.52kW,IP45) | ESOA200-NDK00 | CUC-12H | DPR48/50C | 200A | 480(W)×340(D)×400(H) |
Confirm whether the selected version is installed in a technical room or a protected outdoor location. Verify the exact enclosure protection, ventilation needs, wall load and ambient limits.
Buyer Questions
Answers specific to Wall-Mounted High-Frequency Switch-Mode Power System selection, configuration and purchasing.
No. IP45 is identified for selected WPS configurations only. Request the enclosure rating of the exact model being quoted.
Internal battery accommodation is listed for some taller configurations. Confirm battery dimensions, usable compartment space, weight and thermal requirements on the model drawing.
The range uses different 15 A, 30 A and 50 A module platforms. Module fit, controller support, installed count and current capacity must be reviewed as one configuration.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
Coordinate DC power, distribution, batteries and monitoring around communications loads.
Use integrated or wall-mounted systems where equipment space is limited.
Match generation, storage and power conversion to load and autonomy requirements.
Combine grid, solar, battery or generator inputs around a defined operating strategy.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.