Core equipment rooms
Coordinate DC power, distribution, batteries and monitoring around communications loads.
Configurable rack AC distribution with 1U horizontal or 0U vertical mounting, regional and IEC outlet options, and selectable input current and protection.
The Rack Power Distribution Unit (PDU) organizes AC connections within network, telecom and server cabinets. Its outlet arrangement can be matched to the equipment plug types rather than leaving installers to combine incompatible adapters or multiple loose power strips.
The family supports horizontal 1U and vertical 0U formats, with aluminum-alloy or steel housings. Select the physical format together with the incoming circuit and outlet schedule: a vertical strip may preserve rack units but still needs space beside rails, equipment and cable management.
Specify the destination electrical standard, exact input plug, cable size/length and outlet types/counts. The maximum PDU load is constrained by its approved input, cable and protection arrangement. Confirm whether monitoring is required; the listed mechanical and outlet options do not establish a metering or remote-switching capability.
Huijue Group can review OEM/private-label rack PDU supply and outlet layouts from drawings or samples. Socket combinations, housing length, tooling, electrical tests, production quantity and supplied cords or mounting hardware require engineering confirmation.
Send country/standard, voltage and current, input plug/cable, outlet schedule, 1U/0U mounting dimensions, protection options, monitoring needs and rack quantity.
| Mounting | Horizontal 1U / vertical 0U |
|---|---|
| Rated voltage | 110–250 V AC |
| Rated current | 10 A / 16 A / 32 A; customizable |
| Outlet options | IEC C13 / C19 / universal / UK / US / EU / Schuko |
| Housing | Aluminum alloy / steel |
| Protection | Circuit breaker / overload protection optional |
| Rack compatibility | Standard 19-inch rack |
For indoor rack use or inside a suitable protected cabinet. Check equipment heat, cable access, mounting interference and local electrical requirements.
Buyer Questions
Answers specific to Rack Power Distribution Unit (PDU) selection, configuration and purchasing.
Both are listed outlet options. A mixed schedule can be reviewed against housing space, wiring, input rating and protection requirements.
No. The input assembly and individual outlets have their own limits. Specify the equipment plug types and loads so the complete circuit arrangement can be checked.
That capability is not established by the available record. If needed, state the monitoring and switching functions explicitly for engineering review.
Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.
Coordinate DC power, distribution, batteries and monitoring around communications loads.
Use integrated or wall-mounted systems where equipment space is limited.
Match generation, storage and power conversion to load and autonomy requirements.
Combine grid, solar, battery or generator inputs around a defined operating strategy.
Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.