J1-Series Angle-Steel Cable Runway

J1-Series Angle-Steel Cable Runway

An angle-steel cable-support family with 300–800 mm widths, single or double levels, and finish variants selected for indoor or outdoor routing.

Product Features

Widths of 300, 400, 600 and 800 mm are documented. Outdoor versions use hot-dip galvanizing; indoor versions are listed with electrolytic zinc coating or electrostatic spray. The source includes support and accessory schedules for both layer arrangements.

J1-Series Angle-Steel Cable Runway provides an open steel route for cables around communications installations. It supports installation, fixing and organization of the cable bundle without hiding the route inside a closed channel.

The J1-series table identifies single-layer and double-layer versions. Selecting the complete variant matters: the route width, layer arrangement and finish each affect the bill of materials and how the assembly connects to its supports.

Selection & Configuration

  • Estimate cable load and identify future route additions.
  • Show route width, levels and inter-layer clearance.
  • Confirm hanger or ground-support positions and fixing surfaces.
  • Specify coating requirements by installation exposure.

Account for reinforcement at wide sections and changes of direction in the assembly design. Obtain the approved span and load arrangement for the final model.

Manufacturing & Customization

Huijue Group can assess angle-steel frames to an OEM brief or private-label program using samples and project drawings. Nonstandard sections, joints and coatings require engineering confirmation of tooling, test scope, quantity and delivery responsibilities.

Information for an Accurate Quotation

Provide J1-series identification, widths, lengths, layer count, loading, support spacing and heights, finish, bends, transitions and bonding details.

Technical Parameters

S/NModelNAMETypeWidth (mm)Application scenariossurface treatment
1HJ ZXJ11-J1A3J1-Series Angle-Steel Cable RunwaySingle-Tier300OutdoorHot-Dip Galvanized
2HJ ZXJ11-J1A4J1-Series Angle-Steel Cable RunwaySingle-Tier400OutdoorHot-Dip Galvanized
3HJ ZXJ11-J1A6J1-Series Angle-Steel Cable RunwaySingle-Tier600OutdoorHot-Dip Galvanized
4HJ ZXJ11-J1A8J1-Series Angle-Steel Cable RunwaySingle-Tier800OutdoorHot-Dip Galvanized
5HJ ZXJ21-J1B3J1-Series Angle-Steel Cable RunwaySingle-Tier300(indoor)Electrolytic zinc-coated
6HJ ZXJ21-J1B4J1-Series Angle-Steel Cable RunwaySingle-Tier400(indoor)Electrolytic zinc-coated
7HJ ZXJ21-J1B6J1-Series Angle-Steel Cable RunwaySingle-Tier600(indoor)Electrolytic zinc-coated
8HJ ZXJ21-J1B8J1-Series Angle-Steel Cable RunwaySingle-Tier800(indoor)Electrolytic zinc-coated
9HJ ZXJ21-J1C3J1-Series Angle-Steel Cable RunwaySingle-Tier300(indoor)Electrostatic spraying
10HJ ZXJ21-J1C4J1-Series Angle-Steel Cable RunwaySingle-Tier400(indoor)Electrostatic spraying
11HJ ZXJ21-J1C6J1-Series Angle-Steel Cable RunwaySingle-Tier600(indoor)Electrostatic spraying
12HJ ZXJ21-J1C8J1-Series Angle-Steel Cable RunwaySingle-Tier800(indoor)Electrostatic spraying
13HJ ZXJ12-J1D3J1-Series Angle-Steel Cable RunwayDouble-Tier300OutdoorHot-Dip Galvanized
14HJ ZXJ12-J1D4J1-Series Angle-Steel Cable RunwayDouble-Tier400OutdoorHot-Dip Galvanized
15HJ ZXJ12-J1D6J1-Series Angle-Steel Cable RunwayDouble-Tier600OutdoorHot-Dip Galvanized
16HJ ZXJ12-J1D8J1-Series Angle-Steel Cable RunwayDouble-Tier800OutdoorHot-Dip Galvanized
17HJ ZXJ22-J1E3J1-Series Angle-Steel Cable RunwayDouble-Tier300(indoor)Electrolytic zinc-coated
18HJ ZXJ22-J1E4J1-Series Angle-Steel Cable RunwayDouble-Tier400(indoor)Electrolytic zinc-coated
19HJ ZXJ22-J1E6J1-Series Angle-Steel Cable RunwayDouble-Tier600(indoor)Electrolytic zinc-coated
20HJ ZXJ22-J1E8J1-Series Angle-Steel Cable RunwayDouble-Tier800(indoor)Electrolytic zinc-coated
21HJ ZXJ22-J1F3J1-Series Angle-Steel Cable RunwayDouble-Tier300(indoor)Electrostatic spraying
22HJ ZXJ22-J1F4J1-Series Angle-Steel Cable RunwayDouble-Tier400(indoor)Electrostatic spraying
23HJ ZXJ22-J1F6J1-Series Angle-Steel Cable RunwayDouble-Tier600(indoor)Electrostatic spraying
24HJ ZXJ22-J1F8J1-Series Angle-Steel Cable RunwayDouble-Tier800(indoor)Electrostatic spraying
S/NNameunitquantityREMARK
1Longitudinal Railm2When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail
2Cross MemberCables4The length is the width of the cable runway, and the interval is 250mm.
3pieceNumber of places0.1Ground support, the length meets the height of the machine room
4HangingNumber of places0.67Length meets machine room height
5Installation AccessoriesSleeve1Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack
S/NNameunitquantityREMARK
1Longitudinal Railm4When the length is 1 meter and the width of the cable runway is ≥ 800 mm, the middle position of the cable runway is increased by 1 main rail
2Cross MemberCables8The length is the width of the cable runway, and the interval is 250mm.
3pieceNumber of places0.1Ground support, the length meets the height of the machine room
4HangingNumber of places0.67Length meets machine room height
5Installation AccessoriesSleeve1Other parts (including but not limited to reinforcements, fasteners, grounding wires, etc.) required for complete installation of the wiring rack
6Inter-Tier Support PostsCables1.33Length is double interval, double interval column height ≥ 250mm

Applications

  • Communications-room cable organization.
  • Overhead cable-support routes.
  • Outdoor runs using the specified galvanized variants.

Installation Notes

Match the listed indoor or outdoor model to the site. Provide corrosion exposure and coating specifications when the route operates beyond a normal indoor room.

Buyer Questions

Frequently Asked Questions

Answers specific to J1-Series Angle-Steel Cable Runway selection, configuration and purchasing.

Does angle steel alone define the support capacity?

Capacity also depends on profile dimensions, span, connections and loading. The assembled route needs a confirmed engineering basis.

Which indoor finishes are described?

The table lists electrolytic zinc coating and electrostatic spray for indoor variants. Specify the required option on the order.

Can this frame carry people during maintenance?

The documented function is cable support. A personnel-access structure would require its own verified design and load rating.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Equipment rooms

Organize racks, pathways and service access around active network equipment.

Data centers

Coordinate cabinet capacity, cable routes, airflow and planned expansion.

Edge facilities

Package network equipment within compact distributed infrastructure sites.

Retrofit projects

Add capacity while accounting for existing racks, routes and maintenance space.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.