AC Row-End Power Distribution Cabinet

AC Row-End Power Distribution Cabinet

380 V AC row-end cabinet with CT-based branch metering, local alarm storage and RS485 Modbus plus Ethernet monitoring interfaces.

Product Features

  • Rated 380 V three-phase AC at 50 Hz with 690 V insulation voltage listed.
  • CT measurement of voltage, current, power and energy across main and branch circuits.
  • Configurable multi-level limit/trip alarms with local record storage.
  • RS485 Modbus and Ethernet data upload.
  • Cabinet dimensions configurable from 600–1200 × 300–1200 × 2000–2600 mm.

The AC Row-End Power Distribution Cabinet distributes 380 V three-phase power to equipment-row loads while measuring the incoming and outgoing circuits. Breakers and copper busbars form the primary distribution path; current transformers collect branch and main electrical data for local display and upstream facility monitoring.

Configurable level-based over-limit and trip alarms can be stored locally for maintenance analysis. RS485 Modbus and Ethernet interfaces allow power data to be integrated with a power-and-environment monitoring system in data centers and other high-availability technical rooms.

Selection & Configuration

Start with the row load schedule, diversity, phase balance and redundancy topology. Specify incoming/output current, circuit count, CT ratios, metering points, alarm thresholds and digital I/O. The source design lists Imax 40 kA surge protection and protection rating at least IP30; verify both against the room and coordination study.

Manufacturing & Customization

Huijue Group can review doors, cabinet dimensions, sheet thickness, circuits and OEM/private-label identity from drawings or a sample. Engineering confirms layout feasibility, sheet-metal tooling, the network map, electrical/monitoring tests, production quantity and the factory-to-site delivery boundary.

Information for an Accurate Quotation

  • 380 V single line, fault level and redundancy architecture
  • Main/branch currents, circuit count and load phase
  • CT ratios, alarm thresholds, digital I/O and protocol map
  • Cabinet dimensions, doors, cable entry and finish

Technical Parameters

Key Parameters
Rated operating voltage380 V three-phase AC
Protection rating≥IP30
Operating temperature-5℃~55℃
Dimensions600-1200 × 300-1200 × 2000-2600 mm
Parameter CategoryParameter ItemSpecification
Electrical characteristicsRated operating frequency50 Hz
Rated operating voltage380 V three-phase AC
Rated insulation voltage690 V three-phase AC
Rated impulse withstand voltage≥2.5 kV (50 Hz)
Electrical surge protectionImax=40 kA
Pollution degreeClass III
Protection rating≥IP30
Auxiliary circuit voltageDC +24 V
Operating environmentOperating temperature-5℃~55℃
Storage temperature-20℃~+55℃
Operating relative humidity (30℃)≤80%
Storage relative humidity (40℃±2℃)90%~96%
Atmospheric pressure65~110 kPa
Cabinet dimensionsExternal dimensions(600-1200)×(300-1200)×(2000-2600) mm
Ordering optionsExternal dimensionsCustomizable
Front/rear door styleSingle front & rear / double front & rear / single front / double front
Frame sheet thicknessCustomizable
Protection rating≥IP30
Cabinet paint colorCustomizable
Input current / circuitsConfigured as required
Output current / circuitsConfigured as required
Monitoring functionsInput monitoring / full input-output monitoring / with digital I/O monitoring

Applications

  • Data-center equipment-row AC distribution
  • Government and enterprise critical equipment rooms
  • Telecom core rooms requiring branch-level metering
  • Facilities integrating power data with environmental monitoring

Installation Notes

Published operation is −5°C to 55°C, up to 80% RH at 30°C and 65–110 kPa. The indoor room should provide appropriate cooling, pollution control, grounding, clearances and floor support.

Buyer Questions

Frequently Asked Questions

Answers specific to AC Row-End Power Distribution Cabinet selection, configuration and purchasing.

What electrical data can the cabinet monitor?

The source design collects three-phase voltage, current, power and energy for incoming and branch circuits. Confirm the required accuracy, CT ratios and point list.

Can it connect to an existing monitoring system?

RS485 Modbus and Ethernet interfaces are available. Compatibility depends on the agreed register/point map and the site network architecture.

Are circuit count and cabinet size customizable?

Yes. Huijue Group configures circuits and dimensions around the row schedule, provided busbar, heat, cable and service-clearance checks are satisfied.

Related Products

Application planning

Where this product family fits

Use the deployment context to narrow the configuration before comparing dimensions, capacities and options.

Core equipment rooms

Coordinate DC power, distribution, batteries and monitoring around communications loads.

Compact telecom sites

Use integrated or wall-mounted systems where equipment space is limited.

Outdoor base stations

Match generation, storage and power conversion to load and autonomy requirements.

Hybrid and off-grid nodes

Combine grid, solar, battery or generator inputs around a defined operating strategy.

Before quotation: confirm capacity, interfaces, installation environment, power conditions, quantity and required options.